Tabel cu specificaţiile tehnice pentru SEHVX-AAW / SERHQ-AAW1

SEHVX20AAW / SERHQ020AAW1 SEHVX32AAW / SERHQ032AAW1 SEHVX40AAW / SERHQ020AAW1+SERHQ020AAW1 SEHVX64AAW / SERHQ032AAW1+SERHQ032AAW1
Capacitate de încălzire Nom. kW 21.3 (1), 21.3 (2) 32.1 (1), 32.1 (2) 42.5 (1), 42.5 (2) 63.7 (1), 63.7 (2)
  Max. kW 25.3 (1), 25.3 (2) 38.1 (1), 38.1 (2) 50.5 (1), 50.5 (2) 75.7 (1), 75.7 (2)
Capacitate de răcire Nom. kW 20.7 (3) 30.9 (3) 41.5 (3) 62.3 (3)
  Max. kW 24.7 (3) 36.9 (3) 49.5 (3) 74.3 (3)
Putere intrare Încălzire Nom. kW 6.12 (1), 7.44 (2) 8.72 (1), 11.1 (2) 12.0 (1), 14.7 (2) 16.9 (1), 21.7 (2)
  Răcire Nom. kW 7.59 (3) 13.5 (3) 15.4 (3) 27.4 (3)
COP 2.86 (2), 3.48 (1) 2.89 (2), 3.68 (1) 2.89 (2), 3.54 (1) 2.94 (2), 3.77 (1)
EER 2.73 (3) 2.29 (3) 2.69 (3) 2.27 (3)
Note (1) - Ta de încălzire DB/WB 7/6°C - LWC35°C (DT = 5 °C), date conform EN 14511: 2011 (1) - Ta de încălzire DB/WB 7/6°C - LWC35°C (DT = 5 °C), date conform EN 14511: 2011 (1) - Ta de încălzire DB/WB 7/6°C - LWC35°C (DT = 5 °C), date conform EN 14511: 2011 (1) - Ta de încălzire DB/WB 7/6°C - LWC35°C (DT = 5 °C), date conform EN 14511: 2011
  (2) - Ta de încălzire DB/WB 7/6 °C - LWC 45 °C (2) - Ta de încălzire DB/WB 7/6 °C - LWC 45 °C (2) - Ta de încălzire DB/WB 7/6 °C - LWC 45 °C (2) - Ta de încălzire DB/WB 7/6 °C - LWC 45 °C
  (3) - Răcire: Ta 35°C - LWE 7°C (Dt=5°C), date conform EN 14511: 2011 (3) - Răcire: Ta 35°C - LWE 7°C (Dt=5°C), date conform EN 14511: 2011 (3) - Răcire: Ta 35°C - LWE 7°C (Dt=5°C), date conform EN 14511: 2011 (3) - Răcire: Ta 35°C - LWE 7°C (Dt=5°C), date conform EN 14511: 2011
  (4) - Funcţionarea acestuia se bazează pe gaze fluorurate cu efect de seră (4) - Funcţionarea acestuia se bazează pe gaze fluorurate cu efect de seră (4) - Funcţionarea acestuia se bazează pe gaze fluorurate cu efect de seră (4) - Funcţionarea acestuia se bazează pe gaze fluorurate cu efect de seră